Table 7. Service Processor Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
4068 0312 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-C1-M2
4068 031D Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-C1-M2
x2
4068 0321 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-C1-M6
4068 0322 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-C1-M3
4068 032D Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-C1-M3
x2
4068 0331 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-C1-M5
4068 0332 Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-C1-M4
4068 033D Other bus processor runtime
diagnostics detected memory DIMM
fault
Memory DIMM Location: P1-C1-M4
x2
4068 03FF Other bus processor runtime
diagnostics detected memory failure
on processor card that cannot be
automatically isolated.
Go to “MAP 1540: Minimum
Configuration” on page 52, and run
minimum configuration for further
isolation.
4068 3101 Other bus processor runtime
diagnostics detected RIO port 0 fault
1. RIO port 0, Location: P1-C1
2. System board, Location: P1
4068 3281 Other bus processor runtime
diagnostics detected RIO port 0 fault
1. RIO port 0, Location: P1-C1
2. System board, Location: P1
4068 3284 Other bus processor runtime
diagnostics detected PCI controller
PHB0 fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
4068 3285 Other bus processor runtime
diagnostics detected PCI controller
PHB1 fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
4068 3286 Other bus processor runtime
diagnostics detected PCI controller
PHB2 fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
4069 0001 Memory tests detected system board
fault
Replace the system board. Location:
P1 (See note 3 on page 37.)
4069 0003 Memory tests detected processor
fault
All processors, Location: P1-C1
Chapter 5. Error Code to FRU Index
147