Compex Advanced SerialRAID Adapters SA33-3285-02 Spécifications Page 131

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 457
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 130
Table 5. SPCN Error Codes (continued)
Error Code Description Action/ Possible Failing FRU
1011 9116 SPCN communication failure with
operator panel
1. Operator panel
Location: L1
2. System board
Location: P1
Firmware Error Codes
Attention: If you replace FRUs or perform an action and the problem is still not
corrected, go to “MAP 1540: Minimum Configuration” on page 52 unless otherwise
indicated in the tables.
If you replace FRUs or perform an action and the problem is corrected, go to MAP
410: Repair Checkout in
Diagnostic Information for Multiple Bus Systems
.
Note: Do not shut down the system if the FRU was replaced by hot swap.
Table 6. Firmware Error Codes
Error Code Description Action/ Possible Failing FRU
2011 0xxx Power supply
2011 031y Power supply failure 1. Replace power supply “y”.
2. Check the ac power source.
2022 0000 RIO bus running slow 1. Notify support
2. Processor card, Location: P1-C1
3. System board, Location: P1 (See
note 3 on page 37.)
Chapter 5. Error Code to FRU Index
111
Vue de la page 130
1 2 ... 126 127 128 129 130 131 132 133 134 135 136 ... 456 457

Commentaires sur ces manuels

Pas de commentaire