Vue de la page 89
Infortrend
4-20
Figure 4 - 31: Confirm Box
When a partition of a logical drive/logical volume is deleted, the capacity
of the deleted partition will be added to the previous partition.
WARNING!
Whenever a partition is changed, it is necessary to reconfigure
all host LUN mappings. All data in it will be lost and all host
LUN mappings will be removed when there is any change to the
partition capacity.
If operating in a Unix-based system, reset the subsystem for the
configuration changes to take effect if any changes were made
to partition sizes and partition arrangement.
4.8 Mapping a Logical Volume to Host
LUNs
Select View and Edit Host luns in the Main Menu, then press [ENTER].
Figure 4 - 32: View and Edit Host Luns Screen
A list of host channel/ID combinations appears on the screen. The diagram
above shows two host channels and each is designated with a default ID.
More can be added on each channel.